LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly F0121

Lignum ID-№
F0121
Catalog number
F.2.01.4293
Source of construction assembly
Lignatur, Year 2020
Base structure
Hollow box element
Sheathing
Sheathed left & rightside
Paneling
Without covering
Reference fire protection
VKF Brandschutzanwendung Nr. 15421
Construction height
519 mm
Weight
227 kg/m2
U-value
≈ 0.127 W/m2K
GWP
0.00 kg CO2-eq/m2
Type sound insulation
Measurement
Flat roof / shed roof consisting of a basic construction of hollow box element without cavity insulation in the supporting structure. Sheathed left & rightside, leftside single sheathed rightside single sheathed. Without covering with insulation on top of the sub-floor.
Values of airborne sound insulation
Rw 65 dB
C -2 dB
Ctr -6 dB
Values of footfall sound insulation
Ln,w 49 dB
CI -2 dB
CI50-2500 5 dB

Graphic

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement 40 35 39 44 44 48 51 55 58 62 63 64 65 68 70 71 72 72 71 74 77
Calculation Lignum/Kühn and Blickle 15 18 21 23 26 29 30 30 32 35 38 41 43 45 46 46 46 55 64 71 80 88
Impact sound (Ln) Measurement 40 35 39 44 44 48 51 55 58 62 63 64 65 68 70 71 72 72 71 74 77
Calculation Lignum/Kühn and Blickle 66 66 67 67 67 68 69 72 73 73 73 73 74 75 77 80 83 77 71 67 61 56

Airborne sound (R)

Loading...

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
0
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
0
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
0
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
0.00
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
0.00
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
0.00
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.00
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
0.00
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
0.00
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
0.00
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
0.00
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
0.00
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0.00
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
0.00
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)